Ex-zone 1 and 21
Thermoplastic enclosure
Double insulation
Ex 14: Slow action , change-over contact or 2 NC contacts with double break
ExM 14: Snap action, change-over contact with single or double break
Mounting details toDIN EN 50 047
Suitable for in-line mounting
With pre-wired cable
With gold-plated contacts available on request
With latching element (On-/Off principle) available on request
Version with overlapping contacts available on request (only slow action)
Special version only for dust Ex zone 22 available
N.B.: Please state required approvals for Russia, China, Brazil and North America with your order!
Standards
|
EN 60947-5-1; EN 1088; EN 60079-0, EN 60079-1, EN 60079-31 |
---|---|
Enclosure
|
glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0 |
Degree of protection
|
IP 65 to IEC/EN 60529 |
Contact material
|
silver |
Switching system
|
slow or snap action |
Switching elements
|
Ex 14: change-over contact with double break Zb or 2 NC contacts,
galvanically separated contact bridges; ExM 14: change-over contact with single break C or or double break Za |
Connection
|
cable H05VV-F, 3/4 x 0.75 mm2 |
Uimp
|
4 kV |
Ui
|
250 V |
Ithe
|
Ex 14: T6: 6 A; T5: 3 A ExM 14: T6: 5 A; T5: 3 A |
Ie/Ue
|
Ex 14: 6 A/250 VAC, 0.25 A/230 VDC; ExM 14 1?/1S: 5 A/250 VAC, 0.2 A/230 VDC; ExM 14: 5 A/250 VAC, 0.16 A/230 VDC |
Utilisation category
|
AC-15, DC-13 |
Max. fuse rating
|
Ex 14: 6 A gG/gN-fuse; ExM 14: 5 A gG/gN-fuse |
Ambient temperature
|
Ex 14 and ExM 14 1?/1S: T6: –20°C ... +65°C, T5: -20°C ... +95°C ExM 14: T6: –20°C ... +60°C, T5: -20°C ... +95°C |
Mechanical life
|
> 1 million operations |
Switching frequency
|
1800/h |
Repeat accuracy
|
±0.1 mm |
Contact gap
|
max. 2 x 4 mm |
Note
|
Switch must be protected from mechanical damage! |
Ex marking
|
II 2G Ex d IIC T6/T5 Gb, II 2D Ex tb IIIC T80°C/T90°C Db IP65 IECEx Ex d IIC T6/T5 Gb, Ex tb IIIC T80°C/T90°C Db IP65 |
Approvals
|
Ex 14: PTB 03 ATEX 1070 X IECEx PTB 06.0098X ExM 14: PTB 03 ATEX 1069 X ExM 14 1?/1S: PTB 03 ATEX 1006 X |
防爆行程開關的規(guī)格參數(shù) | |
---|---|
材質 | 其它 |
安裝方式 | 壁掛 |
電壓 | 其它 |
適用場所 | IIA,IIB,IIC | 其他參數(shù) |
產(chǎn)品型號 | Ex 14/ExM 14 |
防爆標志 | Ex II 2G Ex d IIC T6/T5 Gb;Ex II 2D Ex tb IIIC |
供貨周期 | 5-10天 |
防爆合格證編號 | - |
尺寸圖 | - |
違法和不良信息舉報投訴電話:0377-62377728 舉報郵箱:fbypt@ex12580.com